Gate control system to solve common failure analysis Retractable door gated using a 220V electricity, regardless of any fault occurs, first check the voltage used is the number of volts, the voltage is stable, then for others to judge!
- Q: Motor can not start? Div> strong> li>A: div>1, no power, check the power supply; 2, fuse blows, replace the melting device; 3, capacitor breakdown, replacement of capacitors; 4, overload, check whether there are obstacles on the track doorway; 5, thermal protection work, such as 20 minutes after the restart; 6, sensor switch is damaged, replace the sensor switch; 7, line problems, check the strong, weak lines; Div> li>Q: able to open (off), not close (open)? Div> strong> li>A: div>1, sensor switch position is not correct, adjust the position; 2, sensor switch is damaged, replace the sensor switch; 3, COM, and L1, L2 line is connected wrong, the correct connection by road map; 4, Magnetic, and location right off, re-adjust magnet position. Div> li>Q: motor rotation but does not work? Div> strong> li>A: div>1, clutch failure compression spring elastic enough to check, adjust or replace; 2, the clutch is in disengaged position, check whether the handle position closed position; 3, friction clutch compression spring for efficiency, or loose, replace or adjust the spring pressure. Div> li>Q: does not run properly, the wheels spin? Div> strong> li>A: div>1, orbit obstructions, obstacles should be excluded; 2, gear or chain drive failure, need professional repair; 3, the motor screw loose, tighten the screw; 4, wheel bearing is damaged, replace the bearing manufacturer; 5, rain slipping, need to add weight in the nose area. Div> li>Q: "trackless retractable door control system," often go awry is how is it? Div> strong> li>A: div>1, installation, laying the magnet polarity is not uniform, should be corrected, all the magnets of the same pole, that is N pole or S very uniform upward laid; 2, detector mounted against, be rotated 180 ° to install; 3, the nose part of the sprocket type (number of teeth, size, etc.) are inconsistent, leading to the second side of driving wheel speed is inconsistent, should be replaced into a unified model of the sprocket; 4, two-motor function is inconsistent, one of the brake function, while another does not, it should be replaced into a single function with no motor or brake with brake function unified motor; 5, head internal functional circuit failure approach are: the professional maintenance overhaul, or by a professional electrician replace the function of the circuit; Force. Div> li>Q: "trackless retractable door control system", having just taken a while, and then back? Div> strong> li>A: div>1, no laying "trackless retractable door control system" go line magnets, please according to the instruction to install; 2, the magnet is not installed correctly, according to the instruction properly installed; 3, bad or install anti-detector, and first detector rotated 180 ° to install, if the situation is still the same, then replace the detector. Div> li>Q: the remote control, the door was no response, how should I do? Div> strong> li>A: div>1, check whether the control system power, if not, please electricity; 2, check the back labels that handle remote control remote control remote control codes and labels on the back of the receiver part of the remote control codes are the same, if not, then find a unified coding or professional technician, please re-encoding; 3, the circuit itself is the problem, such as Weld, weld, etc., to judge by: 4. In pressing the remote control state power and off, stop keys, listening to the functional head with or without sound relay circuit, and observe the function of circuit indicator on; If nothing happens, please replace the door cable ( connection between the circuit junction box and the function of the line) or check whether there may be reversed; If not, ask someone to repair or replace the function of professional circuit. Div> li>Q: do not rope off the door, which closed at the normal import and declining? Div> strong> li>A: div>1, limit the magnet is not properly installed, please refer to the instructions again to install; 2, infrared anti-collision distance too far, in the head will be within the functional circuit infrared anti-collision distance adjustment knob to adjust the short distance; 3, anti-collision device or bad, from the failure of regulation, the replacement function circuit or the expertise to repair. Div> li>Q: anti-climb device without undue alarm? Div> strong> li>A: div>1, determined as a separate anti-climbing device or with the door control system supporting the use of anti-climb device, if it is a separate anti-climb devices, because they do not use delay function, even if flying insects or leaves drift down encountered anti-climb infrared detection area, the device will alarm; 2, anti-climb probe damage, leading to emission of infrared emission departments can not receive or not receive some of the infrared receiver, the expertise to repair or re-replacement of the probe; 3, installation of retractable doors over uneven pavement sections, resulting in the emission of infra-red receiver can be sometimes, and sometimes can not receive, please refer to repair pavement professionals, or take other measures. Div> li>Q: display light does not shine? Div> strong> li>A: div>1, not power, please correct power; 2, access to display power supply is burned out, replace the power supply; 3, access screen-side power supply reversed polarity, replace the polarity; 4, access screen voltage is too low, please display the appropriate supply voltage to increase. Div> li>Q: scrolling display garbled phenomenon? Div> strong> li>A: div>1, power supply instability, turn off the power again after a few seconds off; 2, the display chip is damaged, replace or re-replacement of professional display; Div> li>
Copyright @ 2010 MIAOSHI DOORINHOUSTRERL CO.,LTD
Service Hotline:400-187-7788